Analisys on the feasibility to modulate lighting systems load: the case study of Palermo
2022
The feasibility to shift and/or modulating the loads that characterize buildings can be useful to improve the performance of smart grids. As known, it is not possible to shift in the time the operating time of the lighting system, but it is possible to modulate the needed electric power. In this paper, the first set of data and a preliminary analysis conducted in the Solarlab of the University of Palermo are presented. The innovative lighting system was designed, sized and installed with the aim of evaluating the consumption of an island user that can be controlled by the DSO or an aggregator. In order to do this, the lighting system load was modulated by applying different strategies: vary…